weld preheater induction
Portable Induction Weld Preheater for Pipe and Steel Plate
Quick Answer
An induction weld preheater uses an alternating-current cable coil to heat conductive metal near a planned weld or heat-treatment zone. This HLQ product page shows portable MYD-10KW, MYD-20KW and MYD-30KW configurations in its original specification image. The published image lists different power, pipe-diameter, current, weight and cable-diameter values for the three models. Actual heating performance and the required temperature cycle depend on the workpiece and the approved procedure.

Table of Contents
- What is the Portable Induction Weld Preheater?
- Key Applications
- Suitable Materials
- Working Principle
- Technical Specifications
- Recommended Model Selection
- Process Workflow
- Common Problems and Solutions
- Engineering Selection Guide
- Advantages and Limitations
- Why Choose HLQ?
- 6 Core FAQs
What is the Portable Induction Weld Preheater?
It is a portable induction heating system presented for localized heating before welding and for related post-weld heating tasks. The original product image shows a power unit, an induction heating cable and a K-type thermocouple. The heater supplies heat to the workpiece; it does not perform the welding operation itself.
The source page also names pipes, steel plate, tanks, boilers and other metal workpieces. These are application categories, not a published list of qualified material grades or weld procedures.

Key Applications
| Application | What the page establishes | What still requires a job-specific procedure |
|---|---|---|
| Pre-weld heating | Pipe and steel plate heating are named. | Target temperature, heated band, hold time and measurement points. |
| Post-weld heating | Pipeline, tank and boiler work are named. | Whether a particular joint requires PWHT and its qualified thermal cycle. |
| Other local heating | Coating, spraying, bending and fitting-related heating are listed. | Suitability of the coil, material and process for the specific task. |
For a separate treatment-focused product, see HLQ’s induction post-weld stress relieving equipment.

The original page includes photographs of field and pipe work. The following PNG arranges four of those same photographs for visual reference; it is not a verified performance case study.
Suitable Materials
Induction heating requires a conductive workpiece and a coil arrangement that couples effectively to the intended heating area. The original page specifically mentions pipeline materials and steel plate, but does not provide a grade-by-grade compatibility list.
| Workpiece | Source-page basis | Selection boundary |
|---|---|---|
| Steel plate | Named in the product description. | Plate grade, thickness and required heating area are not specified. |
| Pipeline or pipe section | Named in the description and shown in original photos. | Pipe material, wall thickness and joint procedure must be checked. |
| Tank or boiler metal workpiece | Named as a post-weld heating application. | No vessel material specification or treatment cycle is supplied. |
| Other conductive metal parts | The page refers generally to large or irregular metal parts. | Compatibility cannot be confirmed from this page alone. |

Working Principle
The MYD power unit drives alternating current through an induction cable positioned around or near the metal workpiece. The changing magnetic field induces currents in the conductive metal, producing localized heating. The source image also shows a K-type thermocouple for temperature sensing. Coil placement, part geometry and material affect the resulting temperature distribution.
For the underlying mechanism, see HLQ’s basic induction heating principle.
| Component | Shown purpose | Published detail |
|---|---|---|
| MYD power unit | Supplies induction heating output. | Three model labels appear in the parameter image. |
| Flexible induction cable | Forms the heating coil at the workpiece. | 10–20 m length and model-dependent cable diameter are printed. |
| K-type thermocouple | Provides a temperature measurement point. | Shown in the original component image; measurement accuracy is not stated. |

Technical Specifications
The following values are transcribed from the parameter image already present on this product page. They are published source values, not independently verified test results. Another HLQ page lists different specifications for some identically named MYD models; confirm the current configuration before applying these values to a project.
| Parameter | MYD-10KW | MYD-20KW | MYD-30KW |
|---|---|---|---|
| Output power | 1–10 kW | 1–20 kW | 1–30 kW |
| Input current | 1–15 A | 1–30 A | 1–40 A |
| Output current | 1–150 A | 1–200 A | 1–250 A |
| Listed heating pipe diameter | 50–400 mm | 50–600 mm | 50–750 mm |
| Unit dimensions | 500 × 350 × 400 mm | 550 × 400 × 450 mm | Not printed in the image |
| Unit weight | 26 kg | 30 kg | 45 kg |
| Induction cable diameter | 10 mm | 13 mm | 15 mm |
| Parameter | Published wording or value | Interpretation limit |
|---|---|---|
| Input voltage | 3 × 380 V, 50/60 Hz | The image does not provide a current revision date. |
| Output frequency | 5–30 kHz | No frequency is assigned to an individual application. |
| Heating temperature | Maximum 900°C | A shared image label, not a qualified setpoint for every model and workpiece. |
| Induction cable length | 10–20 m | Exact supplied length is not identified by model. |
| Temperature sensing | K-type thermocouple shown | Controller accuracy and recording capability are not specified here. |

Recommended Model Selection
Use the original image’s diameter and power entries as an initial screening step. A pipe diameter inside a listed range does not, by itself, establish that a machine can complete the specified heating cycle.
| Model | Published output-power range | Published pipe-diameter range | Additional checks |
|---|---|---|---|
| MYD-10KW | 1–10 kW | 50–400 mm | Wall thickness, heated band, temperature target and available supply. |
| MYD-20KW | 1–20 kW | 50–600 mm | Thermal load, cycle time, cable arrangement and site access. |
| MYD-30KW | 1–30 kW | 50–750 mm | Current electrical data, missing cabinet dimensions and duty requirements. |
For another published portable configuration, compare the portable PWHT welding machine page. Its values for similarly named models differ from the image on this page, so the two tables should be reconciled before use.

Process Workflow
The sequence below is an engineering planning workflow, not a claim that the machine runs an automatic qualified program.
- Identify the workpiece material, geometry and applicable weld or heat-treatment procedure.
- Check the electrical supply, equipment condition and access around the heating zone.
- Position the induction cable and the required temperature measurement point.
- Apply the settings specified by the approved procedure and monitor the measured temperature.
- Verify the required temperature record or inspection result, then allow the workpiece to cool as required.
The original page shows a flexible cable arrangement. HLQ also lists flexible induction heating coils for PWHT and weld preheating as a related product.

Common Problems and Solutions
These are general setup checks for localized induction heating, not a diagnosis of defects in the equipment shown on this page.
| Observed issue | Check first | Why it matters |
|---|---|---|
| Slow temperature rise | Workpiece size, cable placement, available electrical supply and selected power setting. | All affect the heat delivered to the intended zone. |
| Uneven temperature around a joint | Coil spacing, heated-band coverage and temperature measurement locations. | Geometry and placement affect local heating. |
| Unstable temperature indication | Thermocouple contact, position and lead condition. | The published image shows a K-type sensor, but not a measurement-accuracy specification. |
| Model appears undersized | Required temperature cycle, wall thickness and heated mass. | Published pipe diameter alone does not define the thermal load. |

Engineering Selection Guide
For a defensible model choice, collect the job inputs below before treating the image-listed power and diameter ranges as a final selection.
| Input | Reason to record it | Provided on this page? |
|---|---|---|
| Material grade and wall thickness | They affect the required weld procedure and heating load. | No |
| Pipe diameter or plate dimensions | They define coil fit and heated area. | Only model-level pipe-diameter ranges |
| Required temperature cycle | It defines the heating objective and verification points. | No qualified cycle |
| Available electrical supply | It must match the actual unit and operating load. | Image lists three-phase 380 V, 50/60 Hz |
| Cable arrangement and site access | They affect whether the heating zone can be reached and covered. | Image lists 10–20 m cable length |
| Current machine data sheet | It resolves differences between HLQ pages for similarly named MYD models. | Not provided as a dated text document |
A basic electrical plausibility check also matters. Using the image’s three-phase 380 V supply and upper listed input currents, the calculated apparent input is approximately 9.9 kVA for MYD-10KW, 19.7 kVA for MYD-20KW and 26.3 kVA for MYD-30KW. These figures are calculations from published labels, not measured machine results. They should be reconciled with the published 10, 20 and 30 kW maximum output entries.
For a related product presentation, see the portable induction preheat welding machine.

Advantages and Limitations
| Source-supported characteristic | Practical limitation |
|---|---|
| Portable equipment and flexible cable are shown. | Transport dimensions for MYD-30KW and exact supplied cable length are not stated. |
| Three MYD models and pipe-diameter ranges appear in the original image. | The ranges do not guarantee a particular heat-up time or thermal cycle. |
| A K-type thermocouple is shown. | Control accuracy, data logging and recorder specification are not established on this page. |
| The page mentions air cooling. | It gives no model-specific cooling or ambient-temperature specification. |
The source page also lists fitting and unfitting heat among other applications. HLQ’s related induction shrink fitting of shafts and bearings page covers that different heating task.

Why Choose HLQ?
This HLQ page provides original equipment and field photographs, a published three-model MYD comparison image, and visible examples of the heating cable and K-type thermocouple. Those materials help identify the product and frame an engineering review. Because similarly named MYD models have conflicting specifications elsewhere on the same site, the current machine data sheet and project procedure should govern final selection.
6 Core FAQs
1. Is this machine a welder?
No. It is presented as an induction heater for pre-weld and related post-weld heating. It does not create the weld.
2. Which models are shown on the original page?
The original parameter image lists MYD-10KW, MYD-20KW and MYD-30KW.
3. What pipe diameters are listed?
The image lists 50–400 mm for MYD-10KW, 50–600 mm for MYD-20KW and 50–750 mm for MYD-30KW. These are published size ranges, not a guarantee of a specific heating cycle.
4. Is 900°C the required weld-preheat temperature?
No. “Max 900°C” is a shared label in the original parameter image. A required preheat or PWHT temperature must come from the applicable workpiece and approved procedure.
5. What induction cable is listed?
The image lists a 10–20 m cable length and cable diameters of 10 mm, 13 mm and 15 mm for MYD-10KW, MYD-20KW and MYD-30KW respectively.
6. Can a model be selected from pipe diameter alone?
No. Material, wall thickness, heated band, target thermal cycle, available supply and the current model specification also affect selection.