Aluminum Melting Furnace Manufacturer
Industrial Aluminum Induction Melting Furnace Manufacturer
Quick Answer
The HLQ SMJD series is an electric induction melting furnace range documented for aluminum batch capacities from 150 kg to 1200 kg and listed power configurations from 60 kW to 200 kW. The published series data also specifies a 3-phase 380 V, 50–60 Hz supply. Actual melting time, hourly output, energy consumption and operating frequency must be confirmed against the charge material and supplied machine configuration.

What is the Aluminum Induction Melting Furnace?
An aluminum induction melting furnace is an electrically powered system that uses an alternating electromagnetic field to heat a conductive crucible, the metal charge, or both, depending on the supplied furnace configuration. The system normally combines a power converter, induction coil, furnace body, crucible or refractory system, cooling circuit and process controls.
The SMJD series aluminum induction furnace is intended for batch melting applications. The published product documents list aluminum, aluminum alloy, aluminum scrap, aluminum slag and prepared beverage cans among the applicable charge categories.

Induction melting does not by itself determine alloy quality. Charge identification, dryness, contamination, crucible compatibility, temperature control, holding time, dross practice and pouring procedure remain essential parts of the production process.
Key Applications
| Application | Typical charge | Primary engineering concern |
|---|---|---|
| Aluminum alloy casting | Known ingots and approved alloy additions | Alloy identification, temperature control and controlled pouring |
| Production-return remelting | Sorted gates, runners and clean production returns | Preventing alloy mixing and limiting contamination |
| Prepared aluminum scrap melting | Dry, sorted and suitably sized scrap | Moisture exclusion, cleanliness and charge density |
| Beverage-can recycling | Clean and prepared aluminum cans | Coatings, thin-section oxidation and charge preparation |
| Approved slag-recovery process | Aluminum-bearing slag covered by the plant process | Recovery method, material composition and environmental controls |
| Foundry melt supply | Aluminum or aluminum-alloy charge | Batch size, production rhythm, transfer method and melt holding time |
For a page focused specifically on recycled charge preparation, see the HLQ aluminum scrap melting furnace application.

Suitable Materials
| Material category listed by HLQ | Preparation requirement | Selection note |
|---|---|---|
| Aluminum | Known grade, clean and dry | Confirm required batch mass and pour temperature |
| Aluminum alloy | Identify alloy family and permitted additions | Avoid uncontrolled mixing of incompatible alloys |
| Aluminum scrap | Sort, dry, clean and size for safe charging | Bulk density and surface contamination affect the process |
| Aluminum slag | Use only under an approved recovery procedure | Composition and recoverable metal content can vary |
| Prepared beverage cans | Remove prohibited contamination and ensure dryness | Thin material has high surface area and requires controlled practice |

The presence of a material in the manufacturer’s series table does not guarantee identical capacity, melting time or recovery yield for every alloy or scrap form. A final selection requires the actual charge specification.
Working Principle
The published HLQ manual describes the following operating principle. Additional background is available in the company’s guide to induction melting technology.
- Three-phase electrical power enters the power converter.
- The rectifier and control circuit convert the incoming supply into controlled inverter power.
- Alternating current flows through the induction coil.
- The coil produces a rapidly changing magnetic field.
- The changing field induces electrical current in the conductive crucible, metal charge, or both, according to the supplied configuration.
- Electrical resistance converts the induced current into heat.
- Heat raises the aluminum charge to the liquid state.
- The operator monitors the melt and completes the approved dross-removal and pouring procedure.

The electromagnetic heating path depends on crucible conductivity, charge coupling, operating frequency, coil geometry and furnace design. These details must be taken from the final supplied configuration rather than inferred from the model name alone.
Technical Specifications
Published SMJD Melting-Capacity Table
| Model | Power as listed | Steel / stainless steel | Copper / gold / silver | Aluminum / alloy / scrap / slag / cans | Series maximum temperature |
|---|---|---|---|---|---|
| SMJD-463 | 60 kW | 200 kg | 500 kg | 200 kg | 1800°C |
| SMJD-480 | 60 kW | 150 kg | 500 kg | 150 kg | 1800°C |
| SMJD-580 | 80 kW | 200 kg | 600 kg | 200 kg | 1800°C |
| SMJD-600 | 60 kW | 230 kg | 560 kg | 230 kg | 1800°C |
| SMJD-900 | 120 kW | 300 kg | 900 kg | 300 kg | 1800°C |
| SMJD-905 | 80 kW | 300 kg | 900 kg | 300 kg | 1800°C |
| SMJD-1250, 80 kW entry | 80 kW | 400 kg | 1200 kg | 400 kg | 1800°C |
| SMJD-1250, 120 kW entry | 120 kW | 450 kg | 1350 kg | 450 kg | 1800°C |
| SMJD-1500 | 120 kW | 500 kg | 1500 kg | 500 kg | 1800°C |
| SMJD-1550 | 120 kW | 520 kg | 1560 kg | 520 kg | 1800°C |
| SMJD-1700 | 160 kW | 600 kg | 1700 kg | 600 kg | 1800°C |
| SMJD-2300 | 160 kW | 800 kg | 2000 kg | 800 kg | 1800°C |
| SMJD-3100 | 200 kW | 1200 kg | 3000 kg | 1200 kg | 1800°C |
Important: The 1800°C value is reproduced as the published maximum for the overall series. It is not presented here as the recommended aluminum operating temperature.

Published Electrical Parameters
| Model entry | Output power in parameter PDF | Input current | Input supply | Published frequency statement |
|---|---|---|---|---|
| SMJD-463 | 60 kW | 90 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-480 | 60 kW | 90 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-580 | 80 kW | 120 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-600 | 60 kW | 90 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-900 | 120 kW | 180 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-905 | 80 kW | 120 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-1250, 80 kW entry | 80 kW | 120 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-1250, 120 kW entry | 120 kW | 180 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-1500 | 120 kW | 180 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-1550 | 120 kW | 180 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-1700 | 160 kW | 240 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-2300 | 160 kW | 240 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
| SMJD-3100 | 200 kW | 300 A | 3-phase 380 V, 50–60 Hz | 1–100 kHz; custom frequency by request |
The parameter PDF labels these values as output power, while the capacity table labels the power column as input power. The final quotation and electrical drawing should resolve this terminology before installation planning.
Published Crucible Dimensions
| Model | Crucible specification | Upper outer diameter A | Upper inner diameter B | Bottom outer diameter C | Total height H |
|---|---|---|---|---|---|
| SMJD-463 | 463# | 565 mm | 500 mm | 310 mm | 617 mm |
| SMJD-480 | 480# | 510 mm | 420 mm | 400 mm | 710 mm |
| SMJD-580 | 580# | 420 mm | 360 mm | 300 mm | 840 mm |
| SMJD-600 | 600# | 620 mm | 525 mm | 620 mm | 470 mm |
| SMJD-900 | 900# | 520 mm | 425 mm | 510 mm | 960 mm |
| SMJD-905 | 905# | 620 mm | 530 mm | 620 mm | 650 mm |
| SMJD-1250 | 1250# | 620 mm | 535 mm | 620 mm | 850 mm |
| SMJD-1500 | 1500# | 735 mm | 640 mm | 460 mm | 900 mm |
| SMJD-1550 | 1550# | 775 mm | 682 mm | 400 mm | 750 mm |
| SMJD-1700 | 1700# | 610 mm | 500 mm | 610 mm | 1200 mm |
| SMJD-2300 | 2300# | 880 mm | 775 mm | 355 mm | 1000 mm |
| SMJD-3100 | 3100# | 780 mm | 645 mm | 780 mm | 1400 mm |
The parameter sheet specifies tolerances of ±10 mm for A, C and H, and ±5 mm for B. Confirm current crucible drawings and compatibility before purchasing replacement parts.
Original Technical Documents
Recommended Model Selection
| Required aluminum batch capacity | Published model options | Published power | Selection observation |
|---|---|---|---|
| 150 kg | SMJD-480 | 60 kW | Smallest listed aluminum batch |
| 200 kg | SMJD-463 or SMJD-580 | 60 or 80 kW | Same listed capacity with different power configurations |
| 230 kg | SMJD-600 | 60 kW | Confirm cycle-time requirement and charge density |
| 300 kg | SMJD-900 or SMJD-905 | 120 or 80 kW | Same listed capacity with different power configurations |
| 400 kg | SMJD-1250, 80 kW entry | 80 kW | Model designation should be confirmed |
| 450 kg | SMJD-1250, 120 kW entry | 120 kW | Model designation should be confirmed |
| 500 kg | SMJD-1500 | 120 kW | Confirm power margin and planned melts per shift |
| 520 kg | SMJD-1550 | 120 kW | Confirm whether the additional 20 kg is operationally required |
| 600 kg | SMJD-1700 | 160 kW | Check utility and cooling capacity |
| 800 kg | SMJD-2300 | 160 kW | Check transfer and pouring arrangement |
| 1200 kg | SMJD-3100 | 200 kW | Largest aluminum capacity in the published table |
For a related capacity-focused page, review the 300 kg to 1200 kg aluminum melting furnace range.

Batch capacity alone is not enough to select a furnace. Required hourly throughput, charge preparation, alloy, initial charge temperature, holding time, target temperature, available electrical supply, cooling conditions and pouring method can change the appropriate configuration.
Process Workflow
- Define the batch: identify the alloy, required batch mass and downstream casting requirement.
- Inspect the charge: confirm that it is approved, dry, sorted and free from prohibited contamination.
- Inspect the furnace: check the crucible or lining, coil area, cooling circuit, controls and safety interlocks according to the operating procedure.

- Load the furnace: charge material using the approved loading sequence and limits.
- Apply induction power: increase power under the established operating procedure.
- Monitor the melt: track temperature, melt condition, alarms and cooling performance.
- Complete metallurgical treatment: perform approved alloy adjustment and dross or slag removal where required.
- Pour or transfer: use the supplied tilting or transfer system and the plant’s molten-metal procedure.
- Record the batch: document material identity, temperature, processing time and destination.

Common Problems and Solutions
| Observed problem | Checks to perform | Safe response |
|---|---|---|
| No heating or no power output | Incoming supply, phase condition, emergency stop, displayed alarms, cooling interlocks and control status | Stop operation and have trained personnel diagnose the recorded fault; do not bypass an interlock |
| Melting is slower than expected | Actual charge mass, charge form, contamination, power limit, coil coupling, cooling derating and prolonged holding | Compare the operating condition with the confirmed machine configuration before changing settings |
| Temperature reading is unstable | Sensor condition, measurement position, wiring, controller status and calibration procedure | Verify the temperature-measurement system using an approved calibration and operating method |
| Cooling or over-temperature alarm | Water flow, inlet temperature, blockage, leakage, pump operation and heat-exchanger condition | Stop heating and restore the specified cooling condition before restarting |
| Excessive dross or metal loss | Dirty or thin scrap, excessive temperature, long holding time, alloy mixing and unsuitable charge practice | Improve charge preparation and follow the approved time-temperature and metallurgical procedure |
| Crucible or lining deterioration | Cracks, erosion, leakage indications, incompatible charge, thermal cycling and service history | Remove the furnace from service when damage exceeds the approved inspection limit |

Electrical, cooling and molten-metal faults can create serious hazards. Corrective work must follow the supplied manual, the site risk assessment and applicable plant procedures.
Engineering Selection Guide
| Selection input | Information required | Why it matters |
|---|---|---|
| Material | Alloy designation and permitted composition range | Determines charge control and crucible compatibility |
| Charge form | Ingots, returns, scrap, cans or approved slag-recovery material | Affects packing density, contamination and melting behavior |
| Batch requirement | Net aluminum mass per melt | Establishes the minimum documented furnace capacity |
| Production target | Required melts per shift or kilograms per hour | Capacity alone does not establish throughput |
| Temperature requirement | Target melt and pouring-temperature procedure | Influences process control and holding time |
| Electrical supply | Voltage, frequency, phases, available current and transformer capacity | Must match the final power configuration |
| Cooling utilities | Available flow, pressure, inlet temperature and water quality | Protects the coil and power components from overheating |
| Pouring method | Manual, mechanical or hydraulic tilting and transfer height | Affects furnace layout and molten-metal handling |
| Installation area | Foundation, clearances, ventilation, cable routes and guarding | Determines the practical equipment layout |
| Control requirement | Manual control, temperature control, alarms and production records | Defines repeatability and integration scope |
The magnetic field and heating performance are strongly affected by induction heating coil design. Coil geometry, crucible specification and operating frequency should therefore be treated as one engineered system.

Advantages and Limitations
| Potential advantage | Condition or limitation |
|---|---|
| Electric heating without a combustion flame at the charge | The installation still requires high-temperature controls, ventilation and molten-metal safety procedures |
| Adjustable electrical power | Heating performance depends on coupling, charge form, crucible condition and cooling performance |
| Compact batch-melting arrangement | Power cabinet, cooling equipment, clearances and pouring space must be included in the layout |
| Repeatable process control | Repeatability depends on reliable sensing, calibrated instruments and consistent charge preparation |
| Suitable for multiple documented aluminum charge forms | Different scrap forms cannot be assumed to have identical melting rate or recovery yield |
| Reduced direct combustion products at the furnace | Coatings, oils and contaminants in the charge can still produce emissions |
| Optional controlled tilting arrangement | The supplied pouring mechanism and load rating must be verified for each project |
Why Choose HLQ?
- Engineering-based selection: HLQ’s published company information describes a selection process based on material, workpiece or charge size, target temperature, heating time, available power and process objective.
- Documented SMJD range: The official parameter sheet publishes capacity, current, voltage, frequency and crucible-dimension tables for the listed SMJD models.
- Integrated system scope: The product range combines induction power, furnace or crucible assembly, controls and cooling rather than treating the power rating as the complete process.
- Multiple capacity options: The published aluminum capacity entries range from 150 kg to 1200 kg per batch.
- Application support: HLQ publishes product manuals, induction-heating technical information and application material on its own domain.
- Transparent engineering requirement: Final performance should be confirmed from the actual charge, production rate, utility conditions and ordered configuration.

6 Core FAQs
1. What aluminum capacities are listed for the SMJD series?
The published table lists aluminum batch capacities from 150 kg to 1200 kg. Individual entries include 150, 200, 230, 300, 400, 450, 500, 520, 600, 800 and 1200 kg.
2. What electrical supply is shown in the official parameter sheet?
The parameter sheet lists 3-phase 380 V at 50–60 Hz. Published input-current entries range from 90 A to 300 A. The actual installation must be checked against the final electrical drawing and local power system.
3. What operating frequency does the furnace use?
The series document states 1–100 kHz and says that frequency can be customized. This is a broad series statement, not confirmation that one machine operates over the entire range. The configured frequency must be verified for the ordered system.
4. Can the furnace process scrap aluminum and beverage cans?
The manufacturer’s table lists aluminum scrap, aluminum slag and pop cans. The charge must still be correctly identified, dry, prepared and covered by the plant’s approved operating and metallurgical procedure.
5. How should an SMJD model be selected?
Begin with the required net batch mass, then check melts per shift, alloy, charge form, target temperature, available power, cooling utilities, installation area and pouring method. Do not select solely from the kilogram value.
6. Does the 1800°C figure mean aluminum should be melted at 1800°C?
No. The value appears as the maximum-temperature entry for the overall SMJD series table. It should not be interpreted as a recommended aluminum operating setpoint. The approved alloy and process procedure must define the actual temperature range.