Melting Copper Furnace with Induction
Induction Copper Melting Furnace: HLQ DW-MF 15–160 kW
Quick Answer
The HLQ DW-MF induction copper melting furnace is a medium-frequency system for melting copper and other specified metals in a compatible furnace configuration. The published range includes eight models with maximum input ratings from 15 to 160 kW and an operating-frequency range of 1–20 kHz.
The main system consists of a medium-frequency generator, compensation capacitor and melting furnace. An infrared temperature sensor and temperature controller are described as optional additions.
Capacity boundary: The source mentions a general melting range of 3–500 kg but does not assign copper capacities to individual models. Maximum input power, batch capacity and production throughput must be evaluated separately.

What is the Induction Copper Melting Furnace?
An induction copper melting furnace uses an alternating magnetic field to generate heat in a compatible metal charge. The generator, compensation capacitor and furnace coil operate as a matched electrical system.
The DW-MF product description covers melting equipment for copper, brass and several other metals. It does not establish an ore-smelting or metal-extraction process. Charge preparation, crucible or lining selection, temperature measurement and pouring practice remain application-specific.
| Component | Published status | Function |
|---|---|---|
| Medium-frequency generator | Main component | Supplies electrical power to the matched heating system |
| Compensation capacitor | Main component | Forms part of the matched resonant circuit |
| Melting furnace | Main component | Contains the selected charge and heating arrangement |
| Infrared temperature sensor | Optional | Provides temperature measurement when correctly specified and installed |
| Temperature controller | Optional | Supports the selected temperature-control arrangement |

Key Applications
The original page describes factory, college and research use. For this copper-focused product page, the principal task is melting an identified metal charge for a defined downstream operation.
| Application | Melting task | Selection inputs |
|---|---|---|
| Copper batch melting | Prepare a specified mass of molten copper | Grade, charge form, batch mass and required pouring condition |
| Copper-alloy foundry work | Melt a specified alloy in compatible containment | Composition, contamination limits and approved melt practice |
| Metal remelting | Remelt identified, suitably prepared feedstock | Charge cleanliness, geometry, packing and handling requirements |
| Laboratory or research melting | Perform a defined experimental melt | Sample size, measurement needs and repeatability requirements |

Source-Based Application Example
A representative planning scenario is a copper batch melted in a compatible furnace and transferred using the selected pouring arrangement. This is an illustrative application, not a reported customer case with measured performance.
| Record | Required information |
|---|---|
| Charge | Metal grade, charge condition and measured mass |
| Starting condition | Cold or hot furnace, with the condition defined |
| Equipment | Model, crucible or lining, coil configuration and utilities |
| Endpoint | Defined melt or pouring condition and measurement method |
| Results | Measured time, energy use and required metal-quality checks |
The original page also links to a dedicated copper-scrap product. Its feedstock and performance claims should be assessed against its own specification.

Suitable Materials
The source lists copper, brass, steel, stainless steel, silver, gold and aluminum. This is a range of possible applications, not confirmation that one unchanged crucible, lining or electrical configuration is suitable for every listed metal.
| Material | Source status | Required check |
|---|---|---|
| Copper | Primary product application | Grade, charge condition, batch mass and pouring requirements |
| Brass | Explicitly listed | Alloy composition, containment and approved melting practice |
| Steel and stainless steel | Explicitly listed | Separate temperature, lining and electrical-load assessment |
| Silver and gold | Explicitly listed | Contamination limits, compatible tooling and batch size |
| Aluminum | Explicitly listed | Material-specific crucible or lining and melting procedure |
| Unidentified mixed scrap | No universal qualification is provided | Identify and prepare the charge before equipment selection |
For a brass-specific duty, compare the separate brass melting furnace information. Do not transfer capacity figures between metals without confirmation.
Working Principle
- The medium-frequency generator supplies power to a matched coil and compensation-capacitor circuit.
- The furnace coil creates an alternating magnetic field.
- Induced electrical currents generate heat in the compatible conductive load.
- The charge heats and melts within the selected crucible or lining arrangement.
- Electromagnetic forces can produce motion within the molten metal.
- The melt is assessed and transferred using the selected handling and pouring procedure.
The induction heating working principle explains heat generation. Stirring can influence melt behavior, but it does not by itself guarantee composition, cleanliness or casting quality.
The original description states that frequency is selected through the coil and capacitor arrangement according to material, quantity and process requirements. This is an engineered matching task, not permission to change components arbitrarily.

Technical Specifications
The following tables preserve the published values. Maximum input power is not relabelled as output power or useful heat delivered to the metal.
Model Ratings and Published Weights
| Model | Maximum input power | Published weight |
|---|---|---|
| DW-MF-15 | 15 kW | 50 kg |
| DW-MF-25 | 25 kW | 50 kg |
| DW-MF-35 | 35 kW | 65 kg |
| DW-MF-45 | 45 kW | 70 kg |
| DW-MF-70 | 70 kW | 80 kg |
| DW-MF-90 | 90 kW | 94 kg |
| DW-MF-110 | 110 kW | 114 kg |
| DW-MF-160 | 160 kW | 145 kg |
The source does not define whether the weights refer to the generator, another assembly or the complete system. Confirm the scope before planning transport or installation.
Shared Electrical and Operating Information
| Parameter | Published statement | Clarification |
|---|---|---|
| Supply requirement | Three-phase 380 V ±20%, 50 or 60 Hz | Original wording includes “3*380 380V”; confirm the actual machine nameplate |
| Additional voltage row | 70–550 V for all models, labelled “Input voltage” | Electrical location and meaning are not defined; do not treat it as confirmed mains compatibility |
| Operating frequency | 1–20 kHz | Application and matched circuit dependent |
| Common frequency values | Approximately 4, 8, 11, 15 and 20 kHz | Not assigned to individual models |
| Duty statement | 100%; 24-hour work | Cooling, load and ambient conditions are not supplied |
| General melting-capacity statement | 3–500 kg | No metal-specific or model-specific capacity mapping is provided |
| Cold-furnace melting estimate | Approximately 50–60 minutes | Charge, alloy, starting condition and endpoint are not defined |
| Hot-furnace melting estimate | Approximately 20–30 minutes | Not a guaranteed total production-cycle time |
| Temperature measurement | Infrared sensor optional | Model, range and installation are not specified |
| Temperature control | Controller optional | Control architecture and included functions require confirmation |
Published Dimension Groups
| Models | Original dimensions | Limit |
|---|---|---|
| DW-MF-15, DW-MF-25, DW-MF-35 | 27 W × 47 H × 56 L cm | Referenced component is not identified |
| DW-MF-45, DW-MF-70 | 35 × 65 × 65 cm | Dimension order and referenced component are not identified |
| DW-MF-90, DW-MF-110, DW-MF-160 | 40 × 88 × 76 cm | Dimension order and referenced component are not identified |
The original heading “Cubage(cm)” describes linear dimensions, not volume. These values should not be used as the complete installed-system footprint.
Furnace and Pouring Options
| Option | Published information | Required definition |
|---|---|---|
| Tilting furnace | Listed furnace arrangement | Capacity, tilt mechanism and receiving arrangement |
| Push-up furnace | Listed furnace arrangement | Actual lifting and discharge design |
| Stationary furnace | Listed furnace arrangement | Method of melt removal and handling |
| Manual tilting | Listed tilting option | Full-load handling characteristics |
| Electrical tilting | Listed tilting option | Drive, controls and operating limits |
| Hydraulic tilting | Listed tilting option | Hydraulic equipment and operating requirements |

Original catalogue link: document mismatch
The original induction-heating catalogue PDF currently contains pre-weld and post-weld heating equipment information. It is retained as an original link, but it is not a DW-MF copper-melting specification and should not be used to define this furnace.
Recommended Model Selection
Define the alloy, target batch mass, charge form and required operating cycle before choosing a model. The page does not provide enough information to assign a verified copper capacity to each power rating.
| Model | Maximum input rating | Required evaluation |
|---|---|---|
| DW-MF-15 | 15 kW | Confirm charge mass, containment and required melting endpoint |
| DW-MF-25 | 25 kW | Confirm the matched furnace and intended batch duty |
| DW-MF-35 | 35 kW | Evaluate charge geometry, coupling and thermal losses |
| DW-MF-45 | 45 kW | Check the required cycle and pouring arrangement |
| DW-MF-70 | 70 kW | Confirm electrical supply, cooling and furnace configuration |
| DW-MF-90 | 90 kW | Validate representative charge and operating conditions |
| DW-MF-110 | 110 kW | Assess complete utility and handling requirements |
| DW-MF-160 | 160 kW | Confirm actual copper capacity; do not assume the general 500 kg statement applies |
Other induction melting furnace models may publish different configurations. Their capacities and operating conditions must be assessed separately.
Process Workflow
- Define the melt: identify the copper grade or alloy, target mass and required pouring condition.
- Prepare the furnace: verify compatible containment, equipment condition and required utilities.
- Prepare the charge: use identified, suitably dry feedstock and the approved preparation method.
- Load as specified: follow the furnace instructions for charge geometry and loading.
- Melt and monitor: operate within confirmed electrical, cooling and thermal limits.
- Assess the melt: perform the temperature and quality checks required by the process.
- Pour or transfer: use the selected discharge arrangement and receiving equipment.
- Record and inspect: document the batch and inspect the system before the next cycle.
Where powered tilting is required, compare the separately described electric tilting induction melting furnace configuration. Do not assume powered tilting is standard on every DW-MF package.

Common Problems and Solutions
| Observation | Items to investigate | Response |
|---|---|---|
| Melting takes longer than expected | Charge mass, starting condition, delivered power and thermal losses | Compare equivalent batches and defined endpoints before judging performance |
| Required batch does not fit | Usable vessel volume, freeboard and charge packing | Confirm actual working capacity rather than relying on a general kg range |
| Temperature readings appear inconsistent | Sensor setup, viewing conditions and measurement method | Verify the measurement arrangement before changing the process |
| Melt contamination occurs | Charge identity, previous metal, crucible or lining and tools | Review material compatibility and segregation |
| Cooling or thermal alarms occur | Required cooling conditions and equipment condition | Follow the operating instructions and restore confirmed utility conditions |
| Stirring is unsuitable for the process | Charge, power and matched operating frequency | Review the engineered load configuration; do not change matching components arbitrarily |
| Pouring is difficult to control | Mechanism, full load, receiving position and maintenance condition | Assess the complete transfer arrangement |
| Energy use exceeds expectations | Batch mass, hold time, furnace condition and measurement boundary | Use measured energy per defined batch instead of an unqualified efficiency claim |
Original related equipment: aluminum scrap melting
This separate scrap-melting product does not establish acceptance of unidentified scrap in the copper furnace.

Other original equipment: HVAC brazing
Brazing is a separate process from batch melting.

Engineering Selection Guide
A complete melting system must match the metal, charge, furnace containment, electrical circuit, utilities and pouring method.
| Input | Required information | Purpose |
|---|---|---|
| Metal | Copper grade or alloy composition | Select compatible containment and melt practice |
| Batch | Mass, form, dimensions and preparation condition | Determine working capacity and loading arrangement |
| Thermal duty | Starting condition, endpoint and required cycle | Assess heating demand |
| Furnace | Crucible or lining specification and usable volume | Establish containment and batch compatibility |
| Electrical supply | Confirmed voltage, phase, frequency and required capacity | Resolve the source voltage ambiguity and prepare utilities |
| Matched circuit | Coil, capacitor and permitted operating range | Establish electrical compatibility |
| Cooling | Flow, pressure, temperature, water quality and heat rejection | Define actual cooling requirements; values are not published here |
| Temperature measurement | Method, sensor and control requirements | Define the optional temperature system |
| Pouring | Stationary, push-up or tilting arrangement | Plan full-load transfer and receiving equipment |
| Installation | Footprint, clearances, ventilation and access | Prepare the complete working layout |
The induction heating coil must be selected together with the capacitor and furnace load. The published frequency range is not a universal setting for all batch sizes and metals.
Capacity, Throughput and Energy Are Different Measures
| Measure | Definition | Required evidence |
|---|---|---|
| Batch capacity | Metal mass handled in a defined furnace configuration | Alloy, usable vessel volume and operating limits |
| Throughput | Accepted metal output over a complete operating period | Loading, melting, holding, pouring and turnaround times |
| Specific energy | Measured energy divided by a defined metal-mass basis | Meter boundary, mass basis and equivalent process conditions |
| Maximum input power | Published electrical input rating | Not sufficient by itself to calculate the other measures |
Advantages and Limitations
| Feature | Potential benefit | Limit |
|---|---|---|
| Induction heat generation | Provides electrical heating of a compatible load | Performance depends on charge and circuit matching |
| Electromagnetic stirring | Can influence melt circulation | Does not guarantee metal cleanliness or casting quality |
| Eight power ratings | Provide several starting points for selection | No validated copper-capacity mapping is supplied |
| Several furnace arrangements | Allow different handling concepts | Each arrangement requires its own specification |
| Optional temperature equipment | Supports the required monitoring approach | Not confirmed as standard on every system |
| Broad material list | Indicates multiple application possibilities | Containment and operating conditions remain metal-specific |
The original statement that power efficiency is 20% higher than an SCR medium-frequency system lacks a defined test basis. It is not converted here into a guaranteed energy-saving percentage.
General advantages of induction heating should be assessed against the actual furnace, alloy and production conditions.
Why Choose HLQ?
HLQ’s published DW-MF information identifies eight input-power ratings, the three main system components and several furnace and pouring arrangements for technical evaluation.
- Defined power range: published maximum input ratings from 15 to 160 kW.
- System-level description: generator, compensation capacitor and melting furnace.
- Configuration choices: stationary, push-up and tilting arrangements, with several tilting-drive options.
- Optional monitoring: infrared temperature measurement and temperature control can be specified.
Final selection should document the exact metal capacity, supply, cooling, containment, matched circuit and pouring arrangement. The published page does not establish a guaranteed production rate or a universal 500 kg copper capacity.
6 Core FAQs
1. Which models are listed for this induction copper melting furnace?
The page lists DW-MF-15, DW-MF-25, DW-MF-35, DW-MF-45, DW-MF-70, DW-MF-90, DW-MF-110 and DW-MF-160. Their maximum input ratings range from 15 to 160 kW.
2. Does DW-MF-160 melt 500 kg of copper per batch?
The source does not establish that. It gives a general 3–500 kg melting range without assigning copper capacities to individual models. Confirm the actual furnace, containment and alloy capacity.
3. How long does a melting cycle take?
The source estimates 50–60 minutes from a cold furnace and 20–30 minutes from a hot furnace. It does not define the alloy, batch mass or endpoint. These figures are not guaranteed total cycle times or production rates.
4. What electrical supply is required?
The source states three-phase 380 V ±20%, 50 or 60 Hz, but also lists an unexplained 70–550 V row. Use the confirmed nameplate and electrical documentation rather than assuming the wider range is a mains-supply rating.
5. Are temperature control and powered tilting included?
The infrared sensor and temperature controller are described as optional. Manual, electrical and hydraulic tilting are alternative arrangements, so the supplied mechanism must be identified in the configuration.
6. Can the same setup melt copper, brass, steel and aluminum?
The source lists these metals as applications, but it does not confirm that one unchanged setup is suitable for all of them. Crucible or lining, operating conditions, capacity and contamination control must be assessed for each metal.