Air Cooling Induction Heating System

Air Cooled Induction Heating System for Welding Preheating and PWHT

The HLQ MYD Series Air Cooled Induction Heating System is designed for industrial welding preheating, post-weld heat treatment (PWHT), pipeline heating, localized stress relief and controlled heating of metal components.

Available in six published models with nominal output power ratings from 40 kW to 120 kW, the MYD series combines IGBT induction power conversion, PLC-based operation, flexible induction heating coils and multi-point temperature monitoring.

Its air-cooled power system is particularly useful for industrial applications where a compact heating arrangement, flexible workpiece access and controlled temperature management are important.

Typical applications include carbon-steel pipeline welding, pressure-vessel fabrication, welded steel structures, industrial piping systems, tank maintenance and selected thermal assembly processes.

HLQ air cooled induction heating system with PLC controller and flexible induction heating cable
HLQ MYD Series industrial induction heating equipment with power generator, control panel and induction heating arrangement.

Quick Answer

What is an air cooled induction heating system?

An air cooled induction heating system is an industrial heating machine that uses electromagnetic induction to generate heat directly inside electrically conductive metal while using forced air to cool designated power-electronic components.

The HLQ MYD series is primarily designed for weld preheating, pipeline heating, localized metal heating and selected post-weld heat-treatment applications.

The current product page lists six models: MYD-40, MYD-50, MYD-60, MYD-80, MYD-100 and MYD-120, with nominal output ratings of 40–120 kW and a published output frequency range of 2–36 kHz.

Key features: IGBT power conversion, PLC touchscreen operation, flexible induction heating coils, temperature monitoring and air-cooled generator construction.

Engineering note: Air cooling describes the cooling arrangement of the relevant equipment components. The cooling method of each induction coil and output cable must be confirmed for the selected configuration.

Table of Contents

  1. What is an Air Cooled Induction Heating System?
  2. Key Applications
  3. Suitable Materials
  4. Working Principle
  5. Technical Specifications
  6. Recommended Model Selection
  7. Process Workflow
  8. Common Problems and Solutions
  9. Engineering Selection Guide
  10. Advantages and Limitations
  11. Why Choose HLQ?
  12. 10 Core FAQs

What is an Air Cooled Induction Heating System?

An air cooled induction heating system is an electrically powered industrial heating device that converts conventional AC electricity into high-frequency electrical energy.

This electrical energy is delivered to an induction coil positioned around or near a conductive metal workpiece.

The coil generates an alternating magnetic field, which induces electrical currents inside the metal. These currents produce heat through electrical resistance.

Unlike conventional resistance heating, where heat is transferred primarily from an external heating element, induction heating generates heat within the electrically conductive workpiece itself.

The MYD series combines this heating principle with air cooling, digital power control and flexible heating-coil configurations.

Main Components of the MYD Induction Heating System

Component Main Function Engineering Consideration
IGBT Induction Generator Converts electrical input into high-frequency output power. Output rating, frequency, operating duty and conversion losses.
PLC Control System Provides operator control of the heating process. Temperature setpoints, control functions and alarm handling.
Air Cooling System Removes heat from designated equipment components. Airflow, ambient temperature, filtration and ventilation clearance.
Flexible Induction Coil Generates the magnetic field around the workpiece. Coil geometry, insulation, electrical matching and cooling method.
Output Connection Cable Connects the induction generator and heating coil. Length, electrical losses, insulation and permissible routing.
Thermocouple System Measures temperatures at selected locations. Sensor type, number, placement and calibration.
Temperature Recorder Documents the thermal cycle when included. Recording channels, storage, printer and data traceability.
Thermal Insulation Blanket Reduces heat loss from the treatment area. Temperature resistance, thickness and safe placement.

Why Use an Air-Cooled Configuration?

Air-cooled induction heating equipment can simplify installation when the power generator does not require an external cooling-water circuit.

In suitable equipment configurations, this can reduce the need for water pumps, cooling towers, chillers and cooling-water distribution systems.

However, a system described as air cooled should not automatically be considered completely water-free. The generator, induction head and heating cable may have different cooling requirements.

It is therefore important to verify the complete cooling arrangement before equipment selection.

Air Cooling vs. Water Cooling

Comparison Air-Cooled Induction System Water-Cooled Induction System
Primary Cooling Medium Forced air. Circulating water or coolant.
External Water Circuit May not be required for selected configurations. Usually required for water-cooled components.
Installation Potentially simpler where adequate ventilation is available. Requires suitable coolant distribution and heat rejection.
Cooling Capacity Depends on airflow and ambient conditions. Depends on coolant flow, temperature and heat exchanger capacity.
Maintenance Fans, filters, ducts and electronic components. Pumps, water circuits, heat exchangers and water quality.
Low-Temperature Environments Can avoid cooling-water freezing concerns in fully air-cooled configurations. May require freeze protection.
High Ambient Temperature Cooling performance may decrease. Depends on the cooling plant and coolant temperature.
Heavy Continuous Heating Must be checked against thermal rating. Must be checked against coolant and equipment ratings.

Key Applications

The HLQ MYD series is intended for industrial heating applications requiring localized temperature control and flexible induction coil arrangements.

1. Induction Welding Preheating

Welding preheating raises the temperature of the workpiece before welding begins.

For selected steels and welding procedures, preheating helps manage the weld cooling rate, reduce temperature gradients and lower the risk of hydrogen-assisted cracking.

The required temperature depends on the steel grade, carbon equivalent, material thickness, welding consumables, hydrogen control and qualified welding procedure specification (WPS).

For more information, see our induction welding preheating system applications.

2. Post-Weld Heat Treatment (PWHT)

Post-weld heat treatment involves applying a specified thermal cycle to a welded component after welding.

Depending on the material and procedure, PWHT may reduce residual stresses, modify hardness or improve the suitability of a welded assembly for its intended service.

A properly specified PWHT operation normally includes controlled heating, a defined temperature range, an appropriate holding period and controlled cooling.

Temperature measurements and records are essential when compliance with an applicable construction or repair code is required.

HLQ also supplies equipment for induction post weld heat treatment of industrial steel components.

3. Pipeline Induction Heating

Oil, gas, water and petrochemical pipelines often require controlled heating during fabrication, welding and maintenance.

Flexible induction heating cables can be arranged around suitable pipe surfaces to produce a heating zone near the intended weld or treatment location.

Large pipe diameters and thick walls require careful evaluation of electrical power, coil geometry, heat distribution and insulation.

See our technical information about pipeline induction preheating systems.

Industrial pipeline induction heating with flexible cable coil and thermal insulation blankets
Flexible induction heating coils installed around a large steel pipeline with thermal insulation at the heated region.

4. Weld Stress Relief

Welding can produce residual stresses due to localized heating, thermal expansion, contraction and structural restraint.

For appropriate materials and approved procedures, controlled heat treatment can help reduce certain residual stresses in welded assemblies.

The treatment temperature and holding time depend on the steel grade, component thickness and governing standard.

Stress relief should not be confused with ordinary preheating or unrestricted localized heating.

5. Pressure Vessel and Tank Heating

Pressure vessels, tanks and other fabricated steel structures may require localized thermal treatment near weld joints and repaired regions.

Induction heating can be used where the workpiece material, coil layout and thermal procedure permit this heating method.

Thermocouple placement, temperature distribution and heat-treatment records are particularly important for pressure-retaining components.

6. Industrial Steel Structure Heating

Large fabricated beams, frames, support structures and structural steel assemblies can require controlled thermal treatment.

The suitability of induction heating depends on the steel grade, local geometry, structural restraint and maximum allowable temperature.

7. Shrink Fitting and Thermal Assembly

Induction heating can temporarily expand metal components before mechanical assembly.

This technique may be used for selected rings, hubs, bearings, couplings and interference-fit assemblies.

The required heating temperature depends on the interference allowance, component dimensions and coefficient of thermal expansion.

Industrial Application Comparison

Application Typical Workpiece Main Heating Objective Key Control Requirement
Weld Preheating Carbon-Steel Pipe Reach and maintain specified preheat temperature. Preheat and interpass temperature.
PWHT Welded Pipe or Pressure Component Follow an approved heat-treatment cycle. Heating rate, soak, cooling rate and records.
Stress Relief Welded Steel Structure Reduce residual stresses where specified. Material-specific thermal procedure.
Pipeline Heating Oil, Gas or Water Pipeline Provide localized pipe heating. Pipe geometry and temperature distribution.
Pressure Vessel Heating Steel Vessel or Tank Controlled heating of selected regions. Code requirements and thermocouple layout.
Shrink Fitting Steel Hub or Ring Produce temporary thermal expansion. Dimensional clearance and temperature.
Industrial Fabrication Steel Components Localized process heating. Temperature limit and thermal gradients.

Suitable Materials

Induction heating performance depends on the electrical and magnetic properties of the workpiece.

Important parameters include electrical resistivity, magnetic permeability, thermal conductivity, specific heat capacity, material thickness and operating temperature.

Carbon steel is a common material for industrial induction preheating and PWHT because its electrical and magnetic properties can provide favorable electromagnetic coupling.

Material Compatibility Table

Material Compatibility Engineering Consideration
Low-Carbon Steel Generally Suitable Common material for welding preheat and localized heating.
Structural Carbon Steel Generally Suitable Verify thickness, material grade and allowable temperature.
Low-Alloy Steel Application-Dependent Heat treatment must comply with metallurgical requirements.
Cr-Mo Alloy Steel Application-Dependent Often requires carefully defined welding and PWHT procedures.
Austenitic Stainless Steel Requires Evaluation Lower magnetic permeability can influence coupling.
Ferritic Stainless Steel Requires Evaluation Magnetic properties may improve coupling, but temperature limits remain important.
Cast Iron Conditional Thermal cracking and local stress require careful evaluation.
Aluminum Specialized Application Coil and generator matching must be evaluated.
Copper Specialized Application High conductivity affects heating efficiency and coil design.
Plastic or Ceramic Alone Not Directly Suitable Conventional induction heating requires an electrically conductive target.

Important Material Properties

Property Influence on Induction Heating
Electrical Resistivity Influences the generation and distribution of resistive heat.
Magnetic Permeability Affects magnetic coupling and electromagnetic penetration.
Thermal Conductivity Determines how quickly heat spreads to adjacent regions.
Specific Heat Capacity Determines the energy required for a given temperature increase.
Material Thickness Influences thermal mass, penetration requirements and heating time.
Curie Temperature For ferromagnetic materials, magnetic behavior changes significantly near this temperature.
Heat Treatment History Determines whether additional heating may affect mechanical properties.

Working Principle

How Does an Air Cooled Induction Heating System Work?

The working process begins when the induction generator receives three-phase AC electrical power.

The generator’s power electronics convert this input into a controlled high-frequency electrical output.

When the connected induction coil is energized, an alternating magnetic field is produced around the workpiece.

This field induces electrical currents within the electrically conductive material.

The resulting electrical resistance generates heat inside the metal.

For ferromagnetic materials, temperature-dependent magnetic effects also influence the heating process.

Induction Heating Energy Conversion

Stage Operating Process Result
1 Three-Phase AC Input Electrical energy enters the generator.
2 Rectification and IGBT Conversion Electrical energy is converted into high-frequency power.
3 Induction Coil Energization Alternating magnetic field is produced.
4 Electromagnetic Coupling Induced currents are generated in the workpiece.
5 Workpiece Heating Electrical energy is converted into heat.
6 Temperature Monitoring Thermocouples measure selected workpiece temperatures.
7 Power Regulation The control system adjusts heating according to the selected settings.
8 Process Documentation Temperature history can be recorded when suitable instrumentation is included.

Working Principle of Air Cooling

During operation, the induction generator produces internal heat in its semiconductor devices, electrical conductors, magnetic components and other assemblies.

The air-cooling arrangement removes heat from designated equipment components by moving ambient air through or across the relevant cooling structures.

Heat-transfer performance depends on airflow, heat-sink design, ambient temperature and the amount of heat generated by the electrical equipment.

Insufficient airflow can cause excessive internal temperature and reduced operating reliability.

The system must therefore be installed with the ventilation clearance specified for the actual cabinet.

Factors Affecting Heating Efficiency

Factor Effect Recommended Engineering Action
Operating Frequency Influences induced-current distribution. Match the power system and coil to the workpiece.
Coil Geometry Determines magnetic-field distribution. Optimize coil placement and coverage.
Coil-to-Workpiece Coupling Affects energy transfer. Use an appropriate coil configuration.
Steel Wall Thickness Determines thermal mass and through-wall temperature distribution. Calculate heating energy and transient heat transfer.
Thermal Insulation Reduces heat losses. Use suitable high-temperature insulation where approved.
Heating Time Affects temperature rise and heat conduction. Select an appropriate thermal cycle.
Ambient Temperature Affects heat rejection from the generator. Check cooling limits and any power derating.
Working Duty Determines allowable sustained loading. Confirm the actual equipment duty-cycle rating.
Air cooled induction heating equipment with flexible heating coil installed around a steel pipe
Induction heating power supply connected to a flexible coil arrangement around a cylindrical metal workpiece.

Technical Specifications

The following values are based on the published HLQ MYD Series Air Cooling Induction Heating System product information.

Some published values are inconsistent with related MYD datasheets or require clarification. The table should therefore be treated as reference information rather than a certified electrical installation document.

MYD Series Model and Technical Parameters

Parameter MYD-40 MYD-50 MYD-60 MYD-80 MYD-100 MYD-120
Published Output Power 40 kW 50 kW 60 kW 80 kW 100 kW 120 kW
Published Output Frequency 2–36 kHz 2–36 kHz 2–36 kHz 2–36 kHz 2–36 kHz 2–36 kHz
Listed Input Current 60 A 75 A 90 A 120 A 150 A 180 A
Default Input Voltage 380 V 380 V 380 V 380 V 380 V 380 V
Input Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase 3 Phase
Published Machine Weight 130 kg 136 kg 140 kg 145 kg 168 kg 180 kg
Cooling Arrangement Air Air Air Air Air Air
Control Interface PLC PLC PLC PLC PLC PLC
Published Machine Dimensions 800 × 560 × 1350 mm
Published Packing Dimensions 900 × 660 × 1560 mm
Optional Input Voltage Three-phase 220 V or 440 V configurations are mentioned in published MYD information.

Specification verification notes:

  • The output frequency is listed as 2–36 kHz on this product page, while some related MYD pages list 2–30 kHz.
  • The input-current figures require verification because they do not fully reconcile with the stated output power ratings at 380 V.
  • The published cabinet dimensions are shown as a common series value; model-specific confirmation is recommended.
  • The actual duty cycle, output efficiency, power factor and installation requirements should be obtained from the final manufacturer datasheet.
  • The cooling arrangement of the selected coil and connection cable must be confirmed separately.

Control System and Operating Features

Feature Published Description Engineering Clarification
IGBT Power Conversion IGBT-based induction power technology. Actual conversion efficiency requires testing data.
PLC Touchscreen Digital operating interface. Available functions depend on controller configuration.
Temperature Control Adjustable temperature settings. Actual control capability depends on sensors and process dynamics.
Temperature Channels Six channels mentioned in product description. Confirm the number of independent control and monitoring channels.
Temperature Tolerance ±3°C published claim. Measurement conditions and workpiece uniformity are not specified.
Temperature Recording Digital recording with optional printing. Confirm recorder specification and included accessories.
Alarm Functions Fault indication and alarm display. Confirm the available protection functions.
Remote Heating Coil Flexible heating cable and coil arrangements. Confirm coil length, insulation rating and cooling method.
Ambient Temperature Conflicting operating ranges appear in published information. Obtain the approved ambient operating range.

Typical System Accessories

Accessory Application Selection Requirement
Flexible Induction Heating Cable Pipe and irregular workpiece heating. Coil length, insulation and electrical matching.
Clamp-Type Induction Coil Repeatable heating of suitable cylindrical components. Workpiece diameter and available clearance.
High-Temperature Insulation Blanket Reducing heat loss during preheating or PWHT. Temperature rating and approved installation method.
K-Type Thermocouple Measuring selected workpiece temperatures. Temperature range, attachment method and calibration.
Thermocouple Extension Cable Connecting sensors to the measurement system. Correct thermocouple extension type and signal integrity.
Temperature Recorder Documenting heating curves. Channels, accuracy, recording format and traceability.
Output Connection Cable Connecting power generator and coil. Approved length and electrical characteristics.
Temperature Control Interface Managing the thermal process. Application-specific control and alarm functions.

Accessory availability and the final scope of supply must be verified for each model and application.

Choosing an induction heating system requires evaluating the workpiece and heating process rather than selecting a generator solely from its nominal power rating.

Important factors include steel mass, temperature rise, wall thickness, heated area, thermal losses, required heating time and allowable operating duty.

MYD-40 vs. MYD-50 vs. MYD-60 vs. MYD-80 vs. MYD-100 vs. MYD-120

Model Published Output Preliminary Application Focus Selection Considerations
MYD-40 40 kW Localized welding preheating and smaller thermal zones. Pipe thickness, heat loss and operating cycle.
MYD-50 50 kW Moderate industrial preheating requirements. Required temperature rise and heating time.
MYD-60 60 kW General pipeline welding preheating and steel fabrication heating. Coil geometry and average useful heating power.
MYD-80 80 kW Larger heating zones and higher thermal loads. Power supply and workpiece heat distribution.
MYD-100 100 kW Demanding industrial heating applications. Electrical installation and sustained output capability.
MYD-120 120 kW Large workpiece heating and high-power applications. Actual power demand, heating uniformity and duty cycle.

The descriptions above are preliminary engineering guidance. They do not establish guaranteed pipe diameters, processing speeds or continuous-duty ratings for individual models.

Model Selection by Application

Application Initial Model Consideration Main Engineering Question
Localized Pipe Weld Preheating MYD-40 / MYD-50 How much steel must reach the required temperature?
General Industrial Pipeline Heating MYD-50 / MYD-60 What are the pipe dimensions and heating cycle?
Large Steel Fabrication Heating MYD-60 / MYD-80 How much heat is lost to the surrounding structure?
Pressure Vessel Heating MYD-80 / MYD-100 What temperature uniformity and control are required?
Large Thermal Treatment Zones MYD-100 / MYD-120 What average thermal power is required throughout the cycle?
Code-Controlled PWHT Engineering Calculation Required Can the selected configuration follow the qualified thermal profile?

Process Workflow

Step 1: Identify the Workpiece Material

Determine the steel grade, outside diameter, wall thickness, component geometry and material condition.

For alloy steels, review the welding procedure and applicable thermal treatment limits.

Step 2: Define the Required Heating Process

Determine whether the application involves weld preheating, postheating, PWHT, stress relief or another localized thermal process.

Each application may require different temperature limits and control strategies.

Step 3: Calculate the Thermal Load

Estimate the heated workpiece mass and sensible heat requirement.

Account for additional heat conduction into adjacent material, insulation performance and ambient heat losses.

Step 4: Select the Generator and Coil

Choose the preliminary MYD model according to useful heating power, electrical supply and the required operating cycle.

Select a coil arrangement that provides suitable coverage of the target heating region.

Step 5: Prepare the Workpiece

Install the induction heating coil and insulation as required by the approved process.

Position thermocouples at locations appropriate for monitoring the treatment zone.

Step 6: Configure the Temperature Control System

Set the required thermal parameters according to the qualified welding or heat-treatment procedure.

Verify that the temperature monitoring and recording system is functioning correctly.

Step 7: Perform Controlled Heating

Start the induction heating system and monitor the temperature response.

Adjust the heating process within the limits established for the application.

Step 8: Maintain the Required Temperature

For applications requiring a holding period, maintain the specified temperature range for the required duration.

The holding time and acceptance criteria must be established from the relevant material and process requirements.

Step 9: Control Cooling

Follow the specified cooling procedure after heating.

Where necessary, retain suitable insulation to manage the cooling rate and thermal gradients.

Step 10: Inspect and Document the Process

Review temperature records, inspect the treated component and confirm that the heating process meets the specified acceptance criteria.

Process Workflow Summary

Step Operation Quality Requirement
1 Material Identification Confirm material grade and dimensions.
2 Process Definition Establish the applicable heating requirements.
3 Thermal Calculation Estimate required heating energy and power.
4 Equipment Selection Match generator, coil and accessories.
5 Coil Installation Verify electrical insulation and correct placement.
6 Temperature Monitoring Install suitable thermocouples.
7 Controlled Heating Follow the approved heating parameters.
8 Temperature Holding Maintain the specified temperature range.
9 Controlled Cooling Follow the required cooling procedure.
10 Final Inspection Review temperature records and process acceptance.
Induction welding preheating process using flexible heating coils wrapped around a steel pipe
Flexible induction heating cables positioned around a welded steel pipe during industrial heating preparation.

Common Problems and Solutions

The performance of an air cooled induction heating system can be affected by coil matching, workpiece geometry, electrical supply, thermal losses and equipment cooling conditions.

Industrial Induction Heating Troubleshooting Guide

Problem Possible Cause Recommended Solution
Slow Heating Insufficient useful power, poor coupling or excessive heat loss. Check coil configuration, applied power and insulation.
Uneven Temperature Nonuniform coil coverage or local heat sinks. Review coil placement and thermocouple distribution.
Generator Overheating Blocked ventilation, high ambient temperature or excessive operating load. Inspect airflow and verify operating conditions.
Unexpected Power Alarm Electrical supply or system fault. Follow the approved electrical troubleshooting procedure.
Insufficient Heating at Pipe Joint Incorrect treatment-zone width or unfavorable magnetic coupling. Review coil placement and the required heating area.
Temperature Overshoot Control response, sensor placement or excessive applied power. Review control settings and thermocouple installation.
Temperature Recorder Disagreement Sensor error, calibration issue or incorrect wiring. Verify thermocouple type, installation and calibration.
Heating Cable Overheating Excessive current, improper installation or unsuitable cable configuration. Stop heating and inspect the approved cable arrangement.
Excessive Thermal Gradient Insufficient insulation or inadequate heating coverage. Review heating-zone dimensions and thermal insulation.
Unacceptable PWHT Temperature Chart Thermal cycle outside the specified limits. Review the approved procedure and determine corrective action.

For additional applications involving welded assemblies, see the HLQ induction weld stress relieving system information.

Preventive Maintenance Checklist

Inspection Item Recommended Check Purpose
Cooling Fans Check operation and abnormal noise. Maintain sufficient airflow.
Ventilation Openings Inspect for dust and obstruction. Prevent internal overheating.
Power Connections Inspect according to qualified electrical maintenance procedures. Reduce electrical connection faults.
Heating Cables Check insulation and mechanical condition. Maintain safe operation.
Induction Coil Inspect insulation, geometry and approved cooling arrangement. Support repeatable electromagnetic coupling.
Thermocouples Check condition, attachment and calibration. Maintain reliable temperature measurement.
Control System Review alarms and operating records. Identify abnormal operating conditions.
Temperature Recorder Check time, channels and data recording. Support process documentation.

Engineering Selection Guide

Correct power selection begins with the required workpiece heating energy and the time available for the heating process.

For welding preheating and PWHT, the equipment must also provide the required temperature distribution and thermal cycle.

1. Calculate the Heated Steel Mass

For a cylindrical steel pipe with an approximately uniform heated axial band:

m = π × (D − t) × t × L × ρ

Where:

  • m = steel mass in the heated band, kg.
  • D = outside pipe diameter, m.
  • t = pipe wall thickness, m.
  • L = axial length of the selected heated region, m.
  • ρ = steel density, kg/m³.

This calculation uses the geometrical volume of a cylindrical pipe-wall section.

2. Calculate the Thermal Energy Requirement

A preliminary sensible-heat estimate is:

Q = m × Cp × ΔT

Where:

  • Q = thermal energy, kJ.
  • m = heated steel mass, kg.
  • Cp = mean specific heat capacity, kJ/(kg·K).
  • ΔT = required temperature increase, K.

The calculation assumes an approximately uniform temperature increase in the selected steel volume.

In real applications, temperature changes continuously across the pipe wall and along the pipe axis. Heat loss and additional heated metal must also be considered.

3. Example: Induction Preheating a Carbon-Steel Pipe

Consider a hypothetical carbon-steel pipeline welding application with the following requirements:

Parameter Value Unit
Outside Pipe Diameter 323.9 mm
Pipe Wall Thickness 12.7 mm
Selected Axial Heating Length 300 mm
Initial Temperature 25 °C
Target Temperature 175 °C
Temperature Increase 150 K
Assumed Steel Density 7,850 kg/m³
Assumed Mean Specific Heat 0.49 kJ/(kg·K)

Calculated heated steel mass:

m = π × (0.3239 − 0.0127) × 0.0127 × 0.300 × 7850

m ≈ 29.24 kg

Calculated sensible heat:

Q = 29.24 × 0.49 × 150

Q ≈ 2,149 kJ

Converting into kilowatt-hours:

Q = 2149 / 3600

Q ≈ 0.597 kWh

This is the estimated sensible heat required for the selected pipe-wall volume under the stated assumptions.

It is not the measured electrical energy consumption of an MYD generator.

4. Estimate Useful Thermal Power

For a first-order screening calculation:

Puseful = Poutput × ηprocess

Where:

  • Puseful = average useful power entering the selected heated steel region, kW.
  • Poutput = nominal electrical output power of the generator, kW.
  • ηprocess = assumed fraction of output power that becomes useful heat in the selected region.

For this illustrative example only, assume a process factor of 35%.

This value is not a measured efficiency specification for HLQ MYD equipment.

5. Preliminary Heating Time Comparison

Model Published Output Power Assumed Useful Thermal Power Calculated Idealized Heating Time
MYD-40 40 kW 14 kW 154 seconds
MYD-50 50 kW 17.5 kW 123 seconds
MYD-60 60 kW 21 kW 102 seconds
MYD-80 80 kW 28 kW 77 seconds
MYD-100 100 kW 35 kW 61 seconds
MYD-120 120 kW 42 kW 51 seconds

Important engineering clarification: These results are simplified estimates for a hypothetical process. They are not verified heating times, actual PWHT cycle durations, guaranteed productivity figures or tested equipment efficiency data.

Real heating times may be substantially longer because of heat conduction along the pipe, heating outside the selected band, coil-to-workpiece coupling, heat losses, required temperature uniformity and actual equipment operating duty.

6. PWHT Temperature Control Requirements

For post-weld heat treatment, the generator must be selected not only for rapid temperature rise but also for controlled heating and sustained operation over the required treatment period.

The final procedure should specify:

Parameter Engineering Requirement
Initial Temperature Actual workpiece temperature before heating.
Heating Rate Maximum or required rate established by the approved procedure.
Target Temperature Specified PWHT holding-temperature range.
Holding Time Required soak time based on material and procedure.
Temperature Uniformity Permissible variations across the monitored region.
Cooling Rate Controlled cooling requirements.
Thermocouple Placement Positions required by the applicable procedure.
Temperature Records Documented temperature history for process verification.
Applicable Code Project-specific welding, construction or repair standard.

For code-controlled heat treatment, review the relevant induction PWHT equipment configuration, temperature-control requirements and documentation capabilities.

7. Electrical Installation Considerations

The electrical supply must be selected using verified equipment input data.

For a three-phase electrical system, the apparent input power is:

S = √3 × V × I / 1000

Where:

  • S = apparent power, kVA.
  • V = line-to-line voltage, V.
  • I = line current, A.

Actual electrical input power additionally depends on power factor.

Because the published MYD input-current values do not fully reconcile with the stated output ratings at 380 V, final electrical service sizing requires confirmed manufacturer data.

Do not determine circuit-breaker size, conductor size or transformer capacity using only the reference current figures in the original product table.

8. Final Engineering Selection Checklist

Required Information Why It Matters
Workpiece Material Determines magnetic coupling and thermal limits.
Pipe Outside Diameter Influences coil size and heated circumference.
Wall Thickness Determines thermal mass and through-wall response.
Heating Zone Length Determines the approximate heated volume.
Initial Temperature Establishes starting conditions.
Target Temperature Determines the required temperature rise.
Required Heating Time Determines average useful power requirements.
Holding Time Determines sustained heating requirements.
Permitted Cooling Rate Determines process-control requirements.
Electrical Supply Determines site installation requirements.
Ambient Temperature Affects equipment cooling and any derating.
Heating Cable Length Influences electrical matching and site access.
Temperature Recorder Supports thermal-process documentation.
Applicable Welding or PWHT Code Determines acceptance requirements.

Advantages and Limitations

Advantages of Air Cooled Induction Heating

1. Localized and Controlled Heating

Induction heating produces heat inside electrically conductive materials, allowing the process to focus on selected workpiece areas.

2. Flexible Heating-Coil Arrangements

Flexible induction heating cables can be arranged around suitable pipes and other metal components.

This is particularly useful for large fixed structures that cannot easily be moved into a stationary heating furnace.

3. Reduced External Cooling Infrastructure

Where the equipment configuration is fully air cooled, the installation may not require a dedicated cooling-water circuit.

4. Digital Operating Control

PLC-based operation provides an interface for adjusting the heating process and monitoring selected operating parameters.

5. Temperature Monitoring

Thermocouples can provide feedback from selected locations, supporting more controlled heating than an unmonitored heating process.

6. Thermal Process Documentation

A suitable temperature-recording system can document heating curves for inspection and quality-control purposes.

7. Suitability for Industrial Field Work

The equipment can be applied to appropriate large steel components, pipelines and fabricated structures where localized heating is required.

Limitations and Engineering Precautions

Limitation Explanation Recommended Action
Material Compatibility Different metals have different electromagnetic properties. Verify heating feasibility and coil matching.
Air-Cooling Capacity Heat rejection depends on airflow and ambient conditions. Confirm ventilation and environmental limits.
Continuous Operating Duty Sustained operation depends on thermal and electrical ratings. Confirm duty-cycle specifications.
Workpiece Temperature Uniformity Temperature varies according to coil geometry and heat conduction. Use appropriate sensors and qualified heating patterns.
PWHT Compliance A heating machine alone does not establish code compliance. Follow the applicable qualified procedure.
Cable Length Long cables can influence electrical losses and matching. Use approved configurations.
Power Supply Requirements High-power equipment requires an adequately designed electrical installation. Verify rated input kW, kVA and current.
High Ambient Temperature Cooling capacity may decrease as ambient temperature rises. Check derating requirements.
High-Strength Steels Heating may change mechanical properties. Apply material-specific thermal limits.

Induction Heating vs. Resistance Heating vs. Flame Heating

Comparison Induction Heating Resistance Heating Flame Heating
Heating Mechanism Electromagnetic induction. Heat transfer from resistive elements. Combustion heat transfer.
Heat Generated Inside Metal Yes, through induced currents. Usually generated in an external heating element. No, heat is transferred from the flame.
Typical Heat Source Electrical generator and induction coil. Electrical resistance elements. Fuel-gas combustion.
Temperature Monitoring Can use thermocouples and programmable control. Can use thermocouples and programmable control. Depends on the installed control and measurement system.
Localized Heating Well suited to selected geometries. Depends on heating-element placement. Depends on burner positioning and heat distribution.
Heating Large Pipe Sections Possible with suitable flexible coils. Possible with suitable heater blankets. Possible but requires careful temperature control.
Thermal Efficiency Application-dependent. Application-dependent. Application-dependent.
Primary Limitations Electromagnetic coupling and electrical configuration. Element contact, thermal transfer and installation. Combustion hazards and heat distribution.

No universal energy-saving percentage should be assumed when comparing different heating technologies. Actual energy consumption must be determined for the same workpiece, thermal cycle and operating conditions.

Industrial induction heat treatment and stress relieving system with flexible heating coil around steel pipe
Industrial induction heating equipment used with a cylindrical steel workpiece in a fabrication environment.

Why Choose HLQ?

HLQ Induction Equipment Co., Ltd. supplies industrial induction heating equipment for metal heating, thermal processing and related manufacturing applications.

Six Published MYD Power Configurations

The MYD series provides six published output ratings from 40 kW to 120 kW, allowing preliminary model comparison for different industrial heating requirements.

Application-Focused Equipment Selection

Suitable generator selection depends on workpiece dimensions, thermal requirements, operating conditions and the required heating process.

Flexible Heating Solutions

Different coil arrangements can be considered for steel pipes, welded assemblies, large fabricated components and selected industrial structures.

Temperature Monitoring and Process Control

PLC operation, thermocouple monitoring and temperature-recording arrangements can support controlled heating applications when correctly configured.

Industrial Heating Application Coverage

HLQ’s product range includes welding preheating, post-weld heat treatment, pipeline heating, metal processing and other induction heating applications.

Additional engineering information is available for induction heating for pressure vessels and other fabricated industrial equipment.

Engineering Selection Based on Actual Requirements

For reliable equipment selection, the application should be evaluated using actual workpiece dimensions, material properties, required heating temperature, thermal cycle, cooling conditions and available electrical power.

Final equipment specifications and performance requirements should be established from confirmed technical documentation and representative process testing.

10 Core FAQs

1. What is an air cooled induction heating system?

An air cooled induction heating system generates heat inside electrically conductive metal using an alternating magnetic field while using air to cool designated equipment components. Industrial applications include welding preheating, pipeline heating, stress relief and selected post-weld heat-treatment processes.

2. What is the power range of the HLQ MYD series?

The current HLQ MYD product page lists six nominal output power ratings: 40 kW, 50 kW, 60 kW, 80 kW, 100 kW and 120 kW. These correspond to MYD-40, MYD-50, MYD-60, MYD-80, MYD-100 and MYD-120.

3. What is the operating frequency of the MYD induction heater?

The target product page lists an output frequency range of 2–36 kHz. Some related MYD product information lists 2–30 kHz. The actual operating frequency range should be confirmed for the specific generator and coil configuration.

4. Can the MYD series be used for pipeline welding preheating?

Yes. The MYD series is intended for industrial pipeline heating and welding preheating. Correct selection depends on steel grade, pipe diameter, wall thickness, heating-zone length, target temperature and the qualified welding procedure.

5. Is air-cooled induction heating suitable for PWHT?

Air-cooled induction heating equipment can be used for suitable PWHT applications when the generator, heating coil, control system and temperature monitoring equipment meet the required thermal procedure. PWHT compliance depends on the complete process and applicable code, not solely on the heater type.

6. Does an air cooled induction heater require cooling water?

Some air-cooled configurations can operate without an external cooling-water circuit for the power generator. However, the induction coil and output assembly may have separate cooling requirements. The exact configuration must be confirmed before installation.

7. How is the correct induction heater power calculated?

Begin by calculating the mass of the steel region to be heated and the required temperature increase. Estimate the sensible heat using Q = m × Cp × ΔT, then account for heat losses, useful energy transfer, required heating time, operating duty and temperature uniformity.

8. Can the MYD system heat stainless steel?

Potentially. Induction heating can be applied to different stainless-steel grades, but performance depends on electrical resistivity, magnetic permeability, component geometry, coil design and temperature requirements. Application-specific testing is recommended. 9. Can the MYD induction heater operate continuously for 24 hours?

The target product page does not provide sufficient model-specific evidence to guarantee continuous full-power operation for every MYD configuration. Continuous-duty capability should be confirmed from the current manufacturer’s technical datasheet, including ambient-temperature and cooling conditions.

10. What information is required to select the correct MYD model?

The main information includes material grade, workpiece dimensions, initial and target temperatures, required heating time, holding duration, cooling requirements, electrical supply, coil configuration and the applicable welding or heat-treatment procedure. These parameters determine the appropriate power rating and system configuration.

HLQ-air-cooled-induction-heating-system-MYD-brochure

=