Objective
Induction Soldering stainless steel tubes to brass base
Equipment
DW-UHF-6KW-III handheld induction heater
Materials
Customer material
including flux
Key Parameters
Power: 2 kW
Temperature: 482Ā°F (250Ā°C not measured)
Time: 14 -16 sec
Process Steps
Customer process instruction has been followed
DW-UHF-6KW-III induction heating system was limited to 2kW
Results and Conclusions
Sample position according to the coil is vital.Induction Soldering Stainless steel is heated much fasted than the brass. So, the coil is positioned over the brass part (around 95%)